Luiz Pimenta, MD, PhD,a Carlos Fernando Arias Pesántez, MD,a and Leonardo Oliveira, BSc a
 |
INTRODUCTION
Autograft has been the “gold standard” for orthopedic bone grafting applications, but with some clinical challenges.
Here we present the rationale and clinical outcomes supporting the use of a bone substitute material that consists
of a mixture of two calcium phosphates (HA and ß-TCP), which are integrated into a silicon xerogel matrix, promoting
nanocrystalline apatite layers on the surface of the material following implantation into a physiological environment.
METHODS
Twenty-four patients with a median age of 53.80 (36–81) years underwent lumbar spinal fusion for degenerative disease,
selected by clinical presentation, X-rays, and MRI findings. Subjects were evaluated preoperatively and postoperatively
at 1, 3, 6, and 12 months. The outcome assessment consisted of visual analog scale (VAS), Oswestry Disability Index (ODI),
and radiological assessment analyzing the state of fusion on X-ray and CT evaluation by 3 independent radiologists.
RESULTS
All patients completed 12-month follow-up. The mean VAS decreased from 9.3 (± 0.9) to 2.4 (± 1.6) and the mean ODI decreased
from 55.0 (± 9.2) to 19.3 (± 11.4) at 12-month follow-up. Three months after surgery, 10 patients (41.67%) had solid fusion
based on analysis of CT scans and dynamic radiographs. At 6 months postoperatively, the fusion rate had increased to 75%
(18 patients). Twelve months after surgery, 95.83% of patients had solid fusion (23 patients).
 |
CONCLUSIONS
The clinical results from this study of silicon matrix calcium phosphate are consistent with previous in vitro studies
indicating that this material stimulates formation of a bioactive layer and provides an effective bone graft material
for lumbar fusion applications. In comparison with previous studies involving rhBMP-2, silicon matrix calcium phosphate
provided a lower fusion rate at 3- and 6-month follow-up points, but after 12 months, the fusion rate was similar, with
no statistical differences and lower overall costs. No clinically relevant adverse events were associated with either
the cage or graft material. With increasing evidence of high rates of enhanced fusion development in this spinal
application, additional research is encouraged, including longer periods of follow-up, to further confirm the
efficacy of silicon matrix calcium phosphate as a safe and effective bone graft substitute.

Key Words:
Spinal fusion graft, bone substitute, silicon matrix calcium phosphate. SAS Journal. Spring 2008. 2:62–68. DOI: SASJ-2007-0122-RR
|
|
aSanta Rita Hospital, Sao Paulo, Brazil
No funds were received to support this work. No benefits in any form have been or will be received from a commercial party related
directly or indirectly to the subject of this manuscript.
Address correspondence to Luis Pimenta, Department of Minimally Invasive Spinal Surgery, Santa Rita Hospital,
Rua Borges Lagoa, 783 conj 61, São Paulo, São Paulo – 04038-031, Brazil.
This manuscript was submitted August 10, 2007, and accepted for publication
November 8, 2007.
This manuscript was submitted November 7, 2007, and accepted for publication February 29, 2008.
|
|
|
|
Top of Page
|
  |
|
|